GRASEBY 3300 SYRINGE DRIVER

A facility exists that allows the operator to view or print out a history of the patient’s past events. The slave processor also controls the operation of the sounder, connected via PL8. The pump can be run from AC power or from internal rechargeable batteries which give more than eight hours of use. Issue 7 August Service Manual 2 1. Pole clamp assembly renewal The Pole clamp assembly is held in place by two specially manufactured assembly tamper proof screws and the assembly can only be removed with a special screwdriver part number for the shaft and for the handle. Refit the fuse cover ensuring that it goes outside all four spring connectors. April Goals Review pump functionality, sets and accessories Understand key process steps for Starting an infusion Stopping an infusion Changing a container Re-programming the pump Troubleshooting.

Uploader: Vojas
Date Added: 11 January 2017
File Size: 65.60 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 21614
Price: Free* [*Free Regsitration Required]

Later, an infusion rate calculation facility was added to the software.

The wet-side occlusion pressure monitoring made the pump particularly suitable for use in intensive-care baby units. Syringe stiction Stiction for a syringe varies from brand to brand as well as from batch to batch. Also noting the connections, remove all six spade tags. IC7 B to F are Schmitt inverters which add hysteresis to most of the opto outputs.

The patient history will be lost when the clock is reset. This toggle mechanism enables the plunger clamp to be physically swung in or out thus rotating the outer metal tube so that the half nut is either fully engaged or disengaged respectively from the leadscrew.

  ACER IPN 2220 DRIVER DOWNLOAD

” + heading + “

As the motor spindle rotates, the leadscrew rotates and the super nut assembly travels to the left, along the leadscrew. Remove and retain the two screws that hold the board in place and then remove the faulty board. To avoid syphoning of the syringe contents free flowensure that the syringe is correctly loaded into the pump, that the syringe plunger is properly engaged by the pump s actuator and that the pump is placed not more than 80cm above the infusion site.

To change the AC operating voltage settings as fully detailed in the following sections the casing has to be opened and two syring connectors on the Regulator board adjusted.

This derives 5 V from Vcc.

This supply is also used to provide the 5 V DC supply to the logic circuits. To return the pump to its initial set-up mode, press the STOP button. Safety features have been built into the pump and its software. Using a sample garseby and allowing for a safety margin for sticky syringes, adjustments can be made by measuring the thrust generated.

Braun Perfusor ml conversion kit available, see Chap. Please enter up to 7 characters for the postcode.

This document may not be copied or reproduced in whole or in part, or transferred to any More information. Outputs on pins 10, 11 and 12 are used to strobe the switch panel active lowwhich has a 3 x 3 matrix structure.

During the fitting of the new leadscrew the spring assembly may have to be compressed to the left in order to fit it into the grooves in the rear casing. An item that has been previously used. Open the casing see page Take the casing apart 2. Operating Instructions Ultrasound Technologies PD1v vascular pocket doppler Operating Instructions Before using your Pocket Doppler for the first time, please read these operating instructions carefully.

  EMANAGE BLUE USB DRIVER

Infusion Devices

Remove and retain the two screws that hold the transformer in place. This amount is subject to change until you make payment.

Syrjnge vast majority of pumps offered by sellers come with missing keys. This was a basic syringe pump capable of infusions within the range of 0.

Q11 controls the display backlight. Fit a new transparent cover by reversing steps 2 to 5 and close the casing see page A faulty or broken lock housing can be replaced as detailed in the following procedures: Following a significant liquid spill onto the pump, it should be wiped dry and inspected by service personnel before being returned to service.

If the plunger clamp is accidentally dislodged during an infusion the pump will automatically and safely stop infusing and an alarm will sound.

Vertical Display and Storage B We syrinhe that you will be very happy with your purchase however if you are not, please contact us as soon as you recognise the problem.